Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Anal Chim Acta ; 1302: 342473, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38580402

RESUMO

In the medical field, extracellular vesicles (EVs) are gaining importance as they act as cells mediators. These are phospholipid bilayer vesicles and contain crucial biochemical information about their mother cells being carrier of different biomolecules such as small molecules, proteins, lipids, and nucleic acids. After release into the extracellular matrix, they enter the systemic circulation and can be found in all human biofluids. Since EVs reflect the state of the cell of origin, there is exponential attention as potential source of new circulating biomarkers for liquid biopsy. The use of EVs in clinical practice faces several challenges that need to be addressed: these include the standardization of lysis protocols, the availability of low-cost reagents and the development of analytical tools capable of detecting biomarkers. The process of lysis is a crucial step that can impact all subsequent analyses, towards the development of novel analytical strategies. To aid researchers to support the evolution of measurement science technology, this tutorial review evaluates and discuss the most commonly protocols used to characterize the contents of EVs, including their advantages and disadvantages in terms of experimental procedures, time and equipment. The purpose of this tutorial review is to offer practical guide to researchers which are intended to develop novel analytical approaches. Some of the most significant applications are considered, highlighting their main characteristics divided per mechanism of action. Finally, comprehensive tables which provide an overview at a glance are provided to readers.


Assuntos
Vesículas Extracelulares , Ácidos Nucleicos , Humanos , Vesículas Extracelulares/química , Biópsia Líquida/métodos , Biomarcadores/análise , Ácidos Nucleicos/análise , Morte Celular
2.
Commun Chem ; 7(1): 60, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38514757

RESUMO

Despite progress in the prevention and diagnosis of cancer, current technologies for tumor detection present several limitations including invasiveness, toxicity, inaccuracy, lengthy testing duration and high cost. Therefore, innovative diagnostic techniques that integrate knowledge from biology, oncology, medicinal and analytical chemistry are now quickly emerging in the attempt to address these issues. Following this approach, here we developed a paper-based electrochemical device for detecting cancer-derived Small Extracellular Vesicles (S-EVs) in fluids. S-EVs were obtained from cancer cell lines known to express, at a different level, the αvß6 integrin receptor, a well-established hallmark of numerous epithelial cancer types. The resulting biosensor turned out to recognize αvß6-containing S-EVs down to a limit of 0.7*103 S-EVs/mL with a linear range up to 105 S-EVs /mL, and a relative standard deviation of 11%, thus it may represent a novel opportunity for αvß6 expressing cancers detection.

3.
Sensors (Basel) ; 24(5)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38475147

RESUMO

The safeguarding of plant health is vital for optimizing crop growth practices, especially in the face of the biggest challenges of our generation, namely the environmental crisis and the dramatic changes in the climate. Among the many innovative tools developed to address these issues, wearable sensors have recently been proposed for monitoring plant growth and microclimates in a sustainable manner. These systems are composed of flexible matrices with embedded sensing elements, showing promise in revolutionizing plant monitoring without being intrusive. Despite their potential benefits, concerns arise regarding the effects of the long-term coexistence of these devices with the plant surface. Surprisingly, a systematic analysis of their influence on plant physiology is lacking. This study aims to investigate the effect of the color and geometric features of flexible matrices on two key plant physiological functions: photosynthesis and transpiration. Our findings indicate that the negative effects associated with colored substrates, as identified in recent research, can be minimized by holing the matrix surface with a percentage of voids of 15.7%. This approach mitigates interference with light absorption and reduces water loss to a negligible extent, making our work one of the first pioneering efforts in understanding the intricate relationship between plant wearables' features and plant health.


Assuntos
Transpiração Vegetal , Dispositivos Eletrônicos Vestíveis , Transpiração Vegetal/fisiologia , Fotossíntese/fisiologia , Fenômenos Fisiológicos Vegetais , Transporte Biológico , Água , Folhas de Planta/fisiologia
4.
ACS Meas Sci Au ; 4(1): 136-143, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38404486

RESUMO

Nitrite is a compound used as a food additive for its preservative action and coloring capability, as well as an industrial agent for its antifreezing action and for preventing corrosion, and it is also used as a pharmaceutical in cyanide detoxification therapy. However, even recently, because of its high toxicity, it has been used as a murder and suicidal agent due to its affordability and ready availability. In this technical report, we describe an electrochemical paper-based device for selectively determining nitrite in complex biofluids, such as blood, cadaveric blood, vitreous humor, serum, plasma, and urine. The approach was validated in terms of the linearity of response, selectivity, and sensitivity, and the accuracy of the determination was verified by comparing the results with a chromatographic instrumental method. A linear response was observed in the micromolar range; the sensitivity of the method expressed as the limit of detection was 0.4 µM in buffer measurements. The simplicity of use, the portability of the device, and the performance shown make the approach suitable for detecting nitrite in complex biofluids, including contexts of forensic interest, such as murders or suicides in which nitrite is used as a toxic agent. Limits of detection of ca. 1, 2, 4, 5, 3, and 4 µM were obtained in vitreous humor, urine, serum and plasma, blood, and cadaveric blood, also highlighting a satisfactory accuracy comprised between 91 and 112%.

5.
ChemistryOpen ; : e202300203, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38333968

RESUMO

The growth of liquid biopsy, i. e., the possibility of obtaining health information by analysing circulating species (nucleic acids, cells, proteins, and vesicles) in peripheric biofluids, is pushing the field of sensors and biosensors beyond the limit to provide decentralised solutions for nonspecialists. In particular, among all the circulating species that can be adopted in managing cancer evolution, both for diagnostic and prognostic applications, microRNAs have been highly studied and detected. The development of electrochemical devices is particularly relevant for liquid biopsy purposes, and the screen-printed electrodes (SPEs) represent one of the building blocks for producing novel portable devices. In this work, we have taken miR-2115-3p as model target (it is related to lung cancer), and we have developed a biosensor by exploiting the use of a complementary DNA probe modified with methylene blue as redox mediator. In particular, the chosen sensing architecture was applied to serum measurements of the selected miRNA, obtaining a detection limit within the low nanomolar range; in addition, various platforms were interrogated, namely commercial and hand-made SPEs, with the aim of providing the reader with some insights about the optimal platform to be used by considering both the cost and the analytical performance.

6.
Anal Chem ; 96(9): 3698-3706, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38377543

RESUMO

Liquid biopsies have caused a significant revolution in cancer diagnosis, and the use of point of care (PoC) platforms has the potential to bring liquid biopsy-based cancer detection closer to patients. These platforms provide rapid and on-site analysis by reducing the time between sample collection and results output. The aim of this tutorial content is to provide readers an in-depth understanding regarding the choice of the ideal sensing platform suitable for specific cancer-related biomarkers.


Assuntos
Neoplasias , Humanos , Neoplasias/diagnóstico , Biópsia Líquida , Sistemas Automatizados de Assistência Junto ao Leito , Biomarcadores Tumorais/análise
7.
Anal Chem ; 96(6): 2297-2302, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38289028

RESUMO

The COVID-19 pandemic highlighted lateral flow immunoassay (LFIA) strips as the most known point-of-care (POC) devices enabling rapid and easy detection of relevant biomarkers by nonspecialists. However, these diagnostic tests are usually associated with the qualitative detection of the biomarker of interest. Alternatively, electrochemical-based diagnostics, especially known for diabetes care, enable quantitative determination of biomarkers. From an analytical point perspective, the combination of the two approaches might represent a step forward for the POC world: in fact, electrochemical transduction is attractive to be integrated into LFIA strips due to its simplicity, high sensitivity, fast signal generation, and cost effectiveness. In this work, a LFIA strip has been combined with an electrochemical transduction, yielding an electrochemical LFIA (eLFIA). As a proof-of-concept method, the detection of prostate-specific antigen has been carried out by combining a printed-electrochemical strip with the traditional LFIA tests. The electrochemical detection has been based on the measurement of Au ions produced from the dissolution of the gold nanoparticles previously captured on the test line. The analytical performances obtained at LFIA and eLFIA were compared, highlighting how the use of differential pulse voltammetry allowed for a lower detection limit (2.5-fold), respectively, 0.38 and 0.15 ng/mL, but increasing the time of analysis. Although the correlation between the two architectures confirmed the satisfactory agreement of outputs, this technical note has been thought to provide the reader a fair statement with regard to the strength and drawbacks about combining the two (apparently) competitor devices in a diagnostics field, namely, LFIA and electrochemical strips.


Assuntos
Nanopartículas Metálicas , Antígeno Prostático Específico , Humanos , Masculino , Ouro , Pandemias , Imunoensaio/métodos , Biomarcadores , Limite de Detecção
8.
ACS Meas Sci Au ; 3(6): 444-451, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38145023

RESUMO

Since 1940, poly- or perfluorinated alkyl substances (PFAS) have been largely used in many applications, including paints, fire foaming, household items, product packaging, and fabrics. Because of their extremely high persistency, they have been defined as "forever chemicals". Although the EU is taking action to reduce their use, their widespread occurrence in environmental matrices and their harmful effects on human health require the use of highly performing analytical methods for efficient monitoring. Furthermore, novel PFAS are constantly revealed by both EU and National environmental agencies. The objective of this work is to investigate the cause of the signal decrease during the analysis of a standard PFAS mixture in water-based matrices, by proposing an efficient technical procedure for laboratory specialists. The analyses were carried out on a mixture of 30 PFAS, including both regulated and unknown substances (which are expected to be introduced in the guidelines), characterized by different chemical features, using LC-vials of two different materials, namely, glass and polypropylene, and dissolved in two solvents, namely, water and water-methanol. The temperature of analysis and the concentration of PFAS were also considered through LC-MS analyses at different times, in the 0-15 h range. Depending on the chemical structure and length of the PFAS, sampling and treatment procedures may be adopted to tackle the decrease and the release from the containers, reducing the risk of underestimating PFAS also in real water matrices.

9.
Front Microbiol ; 14: 1215529, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37664111

RESUMO

The space race is entering a new era of exploration, in which the number of robotic and human missions to various places in our solar system is rapidly increasing. Despite the recent advances in propulsion and life support technologies, there is a growing need to perform analytical measurements and laboratory experiments across diverse domains of science, while keeping low payload requirements. In this context, lab-on-a-chip nanobiosensors appear to be an emerging technology capable of revolutionizing space exploration, given their low footprint, high accuracy, and low payload requirements. To date, only some approaches for monitoring astronaut health in spacecraft environments have been reported. Although non-invasive molecular diagnostics, like lab-on-a-chip technology, are expected to improve the quality of long-term space missions, their application to monitor microbiological and environmental variables is rarely reported, even for analogous extreme environments on Earth. The possibility of evaluating the occurrence of unknown or unexpected species, identifying redox gradients relevant to microbial metabolism, or testing for specific possible biosignatures, will play a key role in the future of space microbiology. In this review, we will examine the current and potential roles of lab-on-a-chip technology in space exploration and in extreme environment investigation, reporting what has been tested so far, and clarifying the direction toward which the newly developed technologies of portable lab-on-a-chip sensors are heading for exploration in extreme environments and in space.

10.
Angew Chem Int Ed Engl ; 62(51): e202309135, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37672490

RESUMO

Point-of-care (PoC) testing is revolutionizing the healthcare sector improving patient care in daily hospital practice and allowing reaching even remote geographical areas. In the frame of cancer management, the design and validation of PoC enabling the non-invasive, rapid detection of cancer markers is urgently required to implement liquid biopsy in clinical practice. Therefore, focusing on stable blood-based markers with high-specificity, such as microRNAs, is of crucial importance. In this work, we highlight the potential impact of circulating microRNAs detection on cancer management and the crucial role of PoC testing devices, especially for low-income countries. A detailed discussion about the challenges that should be faced to promote the technological transfer and clinical use of these tools has been added, to provide the readers with a complete overview of potentialities and current limitations.


Assuntos
MicroRNAs , Neoplasias , Humanos , Testes Imediatos , Biópsia Líquida , Neoplasias/diagnóstico , Neoplasias/genética , Dispositivos Lab-On-A-Chip , Sistemas Automatizados de Assistência Junto ao Leito
11.
Biosensors (Basel) ; 13(8)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37622863

RESUMO

Biofilms are complex communities of microorganisms that can form on various surfaces, including medical devices, industrial equipment, and natural environments. The presence of biofilms can lead to a range of problems, including infections, reduced efficiency and failure of equipment, biofouling or spoilage, and environmental damage. As a result, there is a growing need for tools to measure and monitor levels of biofilms in various biomedical, pharmaceutical, and food processing settings. In recent years, electrochemical impedance sensing has emerged as a promising approach for real-time, non-destructive, and rapid monitoring of biofilms. This article sheds light on electrochemical sensing for measuring biofilms, including its high sensitivity, non-destructive nature, versatility, low cost, and real-time monitoring capabilities. We also discussed some electrochemical sensing applications for studying biofilms in medical, environmental, and industrial settings. This article also presents future perspectives for research that would lead to the creation of reliable, quick, easy-to-use biosensors mounted on unmanned aerial vehicles (UAVs), and unmanned ground vehicles (UGVs), utilizing artificial intelligence-based terminologies to detect biofilms.


Assuntos
Inteligência Artificial , Incrustação Biológica , Espectroscopia Dielétrica , Biofilmes , Impedância Elétrica
12.
Biosensors (Basel) ; 13(6)2023 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-37366987

RESUMO

Electrochemistry is a genuinely interdisciplinary science that may be used in various physical, chemical, and biological domains. Moreover, using biosensors to quantify biological or biochemical processes is critical in medical, biological, and biotechnological applications. Nowadays, there are several electrochemical biosensors for various healthcare applications, such as for the determination of glucose, lactate, catecholamines, nucleic acid, uric acid, and so on. Enzyme-based analytical techniques rely on detecting the co-substrate or, more precisely, the products of a catalyzed reaction. The glucose oxidase enzyme is generally used in enzyme-based biosensors to measure glucose in tears, blood, etc. Moreover, among all nanomaterials, carbon-based nanomaterials have generally been utilized thanks to the unique properties of carbon. The sensitivity can be up to pM levels using enzyme-based nanobiosensor, and these sensors are very selective, as all enzymes are specific for their substrates. Furthermore, enzyme-based biosensors frequently have fast reaction times, allowing for real-time monitoring and analyses. These biosensors, however, have several drawbacks. Changes in temperature, pH, and other environmental factors can influence the stability and activity of the enzymes, affecting the reliability and repeatability of the readings. Additionally, the cost of the enzymes and their immobilization onto appropriate transducer surfaces might be prohibitively expensive, impeding the large-scale commercialization and widespread use of biosensors. This review discusses the design, detection, and immobilization techniques for enzyme-based electrochemical nanobiosensors, and recent applications in enzyme-based electrochemical studies are evaluated and tabulated.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Ácidos Nucleicos , Reprodutibilidade dos Testes , Técnicas Biossensoriais/métodos , Nanoestruturas/química , Carbono , Técnicas Eletroquímicas/métodos
13.
Small ; 19(51): e2208209, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37096900

RESUMO

Hydrogen peroxide (H2 O2 ) is a primary reactive oxygen species (ROS) that can act as a chemical signal in developing and progressing serious and life-threatening diseases like cancer. Due to the stressful nature of H2 O2 , there is an urgent need to develop sensitive analytical approaches to be applied to various biological matrices. Herein, a portable point-of-care electrochemical system based on MXene-Co3 O4 nanocomposites to detect H2 O2 in different cancer cell-lines is presented. The developed sensor is affordable, disposable, and highly selective for H2 O2 detection. This approach achieves a dynamic linear range of 75 µm with a LOD of 0.5 µm and a LOQ of 1.6 µm. To improve the practical application, the level of ROS is evaluated both in cancer cell lines MDA-MB-231 and DU145, respectively, to breast and prostate cancers, and in healthy HaCat cells. Moreover, the same cancer cells are treated with transforming growth factor-ß1, and MXene-Co3 O4 modified strip is capable to monitorROS variation. The results are satisfactory compared with the cellular ROS fluorescent assay based on DCFH/DCFH-DA. These results open new perspectives for real-time monitoring of cancer progression and the efficacy of the therapy.


Assuntos
Nanocompostos , Neoplasias , Masculino , Humanos , Espécies Reativas de Oxigênio , Peróxido de Hidrogênio/metabolismo , Neoplasias/tratamento farmacológico
14.
Anal Bioanal Chem ; 415(18): 4511-4520, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37000212

RESUMO

MicroRNAs (miRNAs) are clinical biomarkers for various human diseases, including cancer. They have been found in liquid biopsy samples, including various bodily fluids. They often play an important role in the early diagnosis and prognosis of cancer, and the development of simple and effective analytical methods would be of pivotal importance for the entire community. The determination of these targets may be affected by the different physicochemical parameters of the specimen of interest. In this work, an electrochemical detection platform for miRNA based on a screen-printed gold electrode was developed. In the present study, miRNA-21 was selected as a model sequence, due to its role in prostate, breast, colon, pancreatic, and liver cancers. A DNA sequence modified with methylene blue (MB) was covalently bound to the electrochemical strip and used to detect the selected target miRNA-21. After optimization of selected parameters in standard solutions, including the study of the effect of pH, the presence of interferent species, and NaCl salt concentration in the background, the application of square-wave voltammetry (SWV) technique allowed the detection of miRNA-21 down to a limit in the order of 2 nM. The developed device was then applied to several urine samples. In this case too, the device showed high selectivity in the presence of the complex matrix, satisfactory repeatability, and a limit of detection in the order of magnitude of nM, similarly as what observed in standard solutions.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Humanos , Técnicas Eletroquímicas/métodos , Biomarcadores , Ouro , Eletrodos , Limite de Detecção
15.
Biosens Bioelectron ; 227: 115146, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-36821991

RESUMO

Three-dimensional (3D) printed electrochemical devices are increasingly used in point-of-need and point-of-care testing. They show several advantages such as simple fabrication, low cost, fast response, and excellent selectivity and sensitivity in small sample volumes. However, there are only a few examples of analytical devices combining 3D-printed electrodes with electrochemiluminescence (ECL) detection, an electrochemical detection principle widely employed in clinical chemistry analysis. Herein, a portable, 3D-printed miniaturized ECL biosensor for glucose detection has been developed, based on the luminol/H2O2 ECL system and employing a two-electrode configuration with carbon black-doped polylactic acid (PLA) electrodes. The ECL emission is obtained by means of a 1.5V AA alkaline battery and detected using a smartphone camera, thus providing easy portability of the analytical platform. The ECL system was successfully applied for sensing H2O2 and, upon coupling the luminol/H2O2 system with the enzyme glucose oxidase, for glucose detection. The incorporation of luminol and glucose oxidase in an agarose hydrogel matrix allowed to produce ECL devices preloaded with the reagents required for the assay, so that the analysis only required sample addition. The ECL biosensor showed an excellent ability to detect glucose up to 5 mmol L-1, with a limit of detection of 60 µmol L-1. The biosensor was also used to analyse real samples (i.e., glucose saline solutions and artificial serum samples) with satisfactory results, thus suggesting its suitability for point-of-care analysis. Coupling with other oxidases could further extend the applicability of this analytical platform.


Assuntos
Técnicas Biossensoriais , Glucose , Glucose/análise , Luminol , Glucose Oxidase/metabolismo , Smartphone , Peróxido de Hidrogênio , Medições Luminescentes , Técnicas Biossensoriais/métodos , Eletrodos , Impressão Tridimensional , Técnicas Eletroquímicas
16.
Sensors (Basel) ; 23(1)2023 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-36617147

RESUMO

Wearable devices are widely spreading in various scenarios for monitoring different parameters related to human and recently plant health. In the context of precision agriculture, wearables have proven to be a valuable alternative to traditional measurement methods for quantitatively monitoring plant development. This study proposed a multi-sensor wearable platform for monitoring the growth of plant organs (i.e., stem and fruit) and microclimate (i.e., environmental temperature-T and relative humidity-RH). The platform consists of a custom flexible strain sensor for monitoring growth when mounted on a plant and a commercial sensing unit for monitoring T and RH values of the plant surrounding. A different shape was conferred to the strain sensor according to the plant organs to be engineered. A dumbbell shape was chosen for the stem while a ring shape for the fruit. A metrological characterization was carried out to investigate the strain sensitivity of the proposed flexible sensors and then preliminary tests were performed in both indoor and outdoor scenarios to assess the platform performance. The promising results suggest that the proposed system can be considered one of the first attempts to design wearable and portable systems tailored to the specific plant organ with the potential to be used for future applications in the coming era of digital farms and precision agriculture.


Assuntos
Microclima , Dispositivos Eletrônicos Vestíveis , Humanos , Temperatura , Monitorização Fisiológica/métodos
17.
Biosens Bioelectron ; 222: 115005, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36527829

RESUMO

The devastating effects of global climate change on crop production and exponential population growth pose a major challenge to agricultural yields. To cope with this problem, crop performance monitoring is becoming increasingly necessary. In this scenario, the use of sensors and biosensors capable of detecting changes in plant fitness and predicting the evolution of their morphology and physiology has proven to be a useful strategy to increase crop yields. Flexible sensors and nanomaterials have inspired the emerging fields of wearable and on-plant portable devices that provide continuous and accurate long-term sensing of morphological, physiological, biochemical, and environmental parameters. This review provides an overview of novel plant sensing technologies by discussing wearable and integrated devices proposed for engineering plant and monitoring its morphological traits and physiological processes, as well as plant-environment interactions. For each application scenario, the state-of-the-art sensing solutions are grouped according to the plant organ on which they have been installed highlighting their main technological advantages and features. Finally, future opportunities, challenges and perspectives are discussed. We anticipate that the application of this technology in agriculture will provide more accurate measurements for farmers and plant scientists with the ability to track crop performance in real time. All of this information will be essential to enable rapid optimization of plants development through tailored treatments that improve overall plant health even under stressful conditions, with the ultimate goal of increasing crop productivity in a more sustainable manner.


Assuntos
Técnicas Biossensoriais , Agricultura
18.
Lab Chip ; 23(1): 44-61, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36321747

RESUMO

In the field of cancer detection, technologies to analyze tumors using biomarkers circulating in fluids such as blood have developed rapidly based on liquid biopsy. A proactive approach to early cancer detection can lead to more effective treatments with minimal side effects and better long-term patient survival. However, early detection of cancer is hindered by the existing limitations of conventional cancer diagnostic methods. To enable early diagnosis and regular monitoring and improve automation, the development of integrated point-of-care (POC) and biosensors is needed. This is expected to fundamentally change the diagnosis, management, and monitoring of response to treatment of cancer. POC-based techniques will provide a way to avoid complications that occur after invasive tissue biopsy, such as bleeding, infection, and pain. The aim of this study is to provide a comprehensive view of biosensors and their clinical relevance in oncology for the detection of biomarkers with liquid biopsies of proteins, miRNA, ctDNA, exosomes, and cancer cells. The preceding discussion also illustrates the changing landscape of liquid biopsy-based cancer diagnosis through nanomaterials, machine learning, artificial intelligence, wearable devices, and sensors, many of which apply POC design principles. With the advent of sensitive, selective, and timely detection of cancer, we see the field of POC technology for cancer detection and treatment undergoing a positive paradigm shift in the foreseeable future.


Assuntos
Técnicas Biossensoriais , Neoplasias , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Inteligência Artificial , Biomarcadores Tumorais , Biópsia Líquida/métodos , Neoplasias/patologia , Técnicas Biossensoriais/métodos
19.
Lab Chip ; 22(24): 5008, 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36422235

RESUMO

Correction for 'Tailored point-of-care biosensors for liquid biopsy in the field of oncology' by Sima Singh et al., Lab Chip, 2022, https://doi.org/10.1039/d2lc00666a.

20.
Anal Chem ; 94(45): 15558-15563, 2022 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-36318963

RESUMO

The development of electrochemical strips, as extremely powerful diagnostic tools, has received much attention in the field of sensor analysis and, in particular, the detection of nucleic acids in complex matrixes is a hot topic in the electroanalytical area, especially when directed toward the development of emerging technologies, for the purpose of facilitating personal healthcare. One of the major diseases for which early diagnosis is crucial is represented by Alzheimer's disease (AD). AD is a progressive neurodegenerative disease, and it is the most common cause of dementia worldwide. In this context microRNAs (miRNAs), which are small noncoding RNAs, have recently been highlighted for their promising role as biomarkers for early diagnosis. In particular, miRNA-29 represents a class of miRNAs known to regulate pathogenesis of AD. In this work we developed an electrochemical printed strip for the detection of miRNA-29a at low levels. The architecture was characterized by the presence of gold nanoparticles (AuNPs) and an anti-miRNA-29a probe labeled with a redox mediator. The novel analytical tool has been characterized with microscale thermophoresis and electrochemical methods, and it has been optimized by selection of the most appropriate probe density to detect low target concentration. The present tool was capable to detect miRNA-29a both in standard solution and in serum, respectively, down to 0.15 and 0.2 nM. The platform highlighted good repeatability (calculated as the relative standard deviation) of ca. 10% and satisfactory selectivity in the presence of interfering species. This work has the objective to open a way for the study and possible early diagnosis of a physically and socially devastating disease such as Alzheimer's. The results demonstrate the suitability of this approach in terms of ease of use, time of production, sensitivity, and applicability.


Assuntos
Doença de Alzheimer , Técnicas Biossensoriais , Nanopartículas Metálicas , MicroRNAs , Doenças Neurodegenerativas , Humanos , Ouro/química , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/genética , Nanopartículas Metálicas/química , Biomarcadores , MicroRNAs/análise , Técnicas Biossensoriais/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...